CDC and DA are the 2 approval pathways for a granny flat in NSW. CDC is a tick-the-boxes approval issued by a private certifier: if your block meets every standard, it cannot be refused. DA is a merit assessment by your council, used when your block does not meet those standards. CDC is faster and cheaper. DA is the fallback, not a failure.

Which one applies to you is not a choice. It is determined by your block.

The rule that decides it

Both pathways sit under the State Environmental Planning Policy (Housing) 2021. The complying development standards for secondary dwellings are in Schedule 1 of that policy.

The logic is simple. Meet every standard in Schedule 1, and you qualify for CDC. Miss any one of them, and you go to DA.

There is no partial credit and no negotiating with a certifier. A certifier has no discretion, which is exactly why CDC is fast. A council does have discretion, which is why DA takes longer but can approve things CDC never could.

Side by side

CDC
DA
Who decides
Private certifier
Local council
Basis of decision
Compliance with a fixed checklist
Merit assessment
Can it be refused if compliant
No
Yes, it is assessed on merit
Neighbour notification
Not required
Usually required
Typical cost
Lower
Higher, plus council fees and consultant reports
Typical timeframe
Weeks
Months
Flexibility on design
None, standards are fixed
Variations can be argued
CDC
Private certifier
DA
Local council
CDC
Compliance with a fixed checklist
DA
Merit assessment
CDC
No
DA
Yes, it is assessed on merit
CDC
Not required
DA
Usually required
CDC
Lower
DA
Higher, plus council fees and consultant reports
CDC
Weeks
DA
Months
CDC
None, standards are fixed
DA
Variations can be argued

BlueGum’s published timeframes are 4 to 6 weeks for CDC and 3 to 6 months for DA. Those are indicative. Council workload, requests for further information, and site complexity all move them.

The standards your block has to meet for CDC

This is the part most guides get wrong. Nearly every article you will read states NSW setbacks as flat numbers, usually “900mm to the side and 3m to the rear”. Those figures are only correct for one band of lot sizes. The standards are tiered by how big your lot is.

Here is what Schedule 1 actually says.

Lot size and zoning

  • Minimum lot area of 450 m² (section 54(2)(c))
  • Land in a residential zone. Zone R5 Large Lot Residential is excluded from CDC, even though a granny flat is permitted there with consent (section 54(1)(a))
  • Only one principal dwelling and one secondary dwelling on the lot when finished
  • The lot cannot later be subdivided (section 51)
  • On a battle-axe lot, the access laneway is excluded when working out the lot area

Floor area

Capped at 60 m², unless another planning instrument covering your land allows more (section 52(2)(c)). This is a hard ceiling on both pathways, not just CDC.

Frontage, measured at the building line

Lot area
Minimum frontage
450 m² to 900 m²
12 m
Over 900 m² to 1,500 m²
15 m
Over 1,500 m²
18 m
Minimum frontage
12 m
Minimum frontage
15 m
Minimum frontage
18 m

Height

Maximum 8.5 m above existing ground level for the granny flat itself. Detached outbuildings are capped at 4.8 m and fences at 1.8 m.

Side setbacks

Lot area
Minimum side setback
450 m² to 900 m²
0.9 m
Over 900 m² to 1,500 m²
1.5 m
Over 1,500 m²
2.5 m
Minimum side setback
0.9 m
Minimum side setback
1.5 m
Minimum side setback
2.5 m

Then add 25% of any building height above 3.8 m. A 5 m tall granny flat on a 600 m² block needs 0.9 m plus 25% of 1.2 m, so 1.2 m in total.

Rear setbacks

Lot area
Base setback
Extra for height over 3.8 m
Maximum
450 m² to 900 m²
3 m
3× the height above 3.8 m
8 m
Over 900 m² to 1,500 m²
5 m
3× the height above 3.8 m
12 m
Over 1,500 m²
10 m
3× the height above 3.8 m
15 m
Base setback
3 m
Extra for height over 3.8 m
3× the height above 3.8 m
Maximum
8 m
Base setback
5 m
Extra for height over 3.8 m
3× the height above 3.8 m
Maximum
12 m
Base setback
10 m
Extra for height over 3.8 m
3× the height above 3.8 m
Maximum
15 m

The height loading catches people out. On a 600 m² block, going from 3.8 m to 4.8 m tall pushes the rear setback from 3 m to 6 m, which can cost you the whole building envelope.

Front setback

Normally the average of the 2 nearest dwelling houses on the same side of the street within 40 m. If there are not 2 within 40 m, it falls back to 4.5 m for lots between 450 m² and 900 m², 6.5 m up to 1,500 m², and 10 m above that. Classified roads require 9 m.

Landscaped area

Lot area
Minimum landscaped area
450 m² to 600 m²
20%
Over 600 m² to 900 m²
25%
Over 900 m² to 1,500 m²
35%
Over 1,500 m²
45%
Minimum landscaped area
20%
Minimum landscaped area
25%
Minimum landscaped area
35%
Minimum landscaped area
45%

At least half of that landscaped area has to sit behind the building line.

Things CDC will not cover

  • Basements
  • A roof terrace on the topmost roof
  • Land the Codes SEPP excludes, which includes certain environmentally sensitive land and heritage items

Bush fire prone land, flood control lots and land near the Siding Spring Observatory have their own additional standards in sections 57 to 59.

What if your block does not qualify?

You go to DA. That is not a dead end, and it is worth being clear about why.

A DA is assessed on merit, which means council weighs the proposal against its own planning controls and can approve something that does not fit the CDC checklist. Plenty of granny flats that fail CDC by a small margin get approved through DA without much drama.

Common reasons a Sydney block ends up on the DA path:

  • Lot slightly under 450 m², which is very common in the inner and middle ring
  • Frontage under the tier threshold, particularly on older subdivided blocks
  • Heritage listing or a heritage conservation area
  • Flood affected land
  • Bush fire prone land above the lower BAL ratings
  • An existing structure or tree that cannot be moved
  • Zone R5

DA costs more and takes longer. It is still an approval.

The honest answer on timeframes

You will see CDC timeframes quoted as 10 to 20 business days. That figure comes from certifier practice, not from the legislation, and it assumes a complete application with nothing outstanding. The clock in practice starts when your documents are actually finished, not when you first ring a builder.

Realistically, the drawings, survey, soil test and BASIX certificate take longer than the certifier does.

Share with

Frequently asked
questions

Effectively yes. A certifier has no discretion to refuse a complying development application that meets every standard. That is the entire point of the pathway. The risk is not refusal, it is discovering partway through that your block misses one standard.

Often, yes. A DA is a merit assessment, so council can approve a proposal that does not meet the fixed CDC checklist. It takes longer and costs more, and the outcome is not guaranteed the way a compliant CDC is.

It has to be at least 450 m². For a battle-axe block, the access handle is not counted, so a lot that looks like 480 m² on the title can fall under the threshold once the laneway is excluded.

No. Section 51 of the Housing SEPP prevents subdivision of a lot where a secondary dwelling has been built under that part. The granny flat stays on the same title as the house.

A builder or certifier does, from your survey, title and the planning controls on your land. BlueGum handles both CDC and DA approvals in-house and assesses which one applies as part of the site assessment.

Find out which pathway your block is on

The tiered standards above mean 2 blocks on the same street can land on different pathways. The only way to know is to check your specific lot area, frontage and zoning.

Check your block, or call BlueGum on 1300 060 651.

Building granny flats since

Since 2012

Builder licence

247388C, verifiable through NSW Fair Trading

Industry body

Housing Industry Association member

MBA NSW Excellence in Housing Awards

Winner 2021, Winner 2023, Finalist 2020

Completed granny flats documented on this site

70+

Approvals

CDC and DA, both managed in-house

Pricing

Fixed price after a site assessment, 2-bedroom from $134,990

Building granny flats since

Since 2012

Builder licence

247388C, verifiable through NSW Fair Trading

Industry body

Housing Industry Association member

MBA NSW Excellence in Housing Awards

Winner 2021, Winner 2023, Finalist 2020

Completed granny flats documented on this site

70+

Approvals

CDC and DA, both managed in-house

Pricing

Fixed price after a site assessment, 2-bedroom from $134,990

BlueGum Granny Flats is a licensed NSW builder, licence number 247388C, and a member of the Housing Industry Association. Setback, frontage and landscaping figures are drawn from the State Environmental Planning Policy (Housing) 2021 as in force in August 2026 and are general information, not planning advice. Other planning instruments applying to your land can vary them. Confirm the requirements for your block with a certifier or your council. Cost ranges are drawn from published 2026 Sydney market guides and are not a quote.
Check my block Call 1300 060 651